Geberit - PE-HD
Produktbild
Unfortunately, you cannot purchase this item from us.
Crassus provides this piping system purely for informational purposes within the context of the Pipe Lexicon.

Dimension
Pipe end
Properties
Material category Plastic
RXNR 9-9-S
Designation Geberit - PE-HD
Manufacturer Geberit
DN 160
Pipe end Spigot
Material name Polyethylen with high density (PE-HD)
Color (exterior) Black
Applications Industry, Civil Engineering, HVAC/MEP Sector, Drainage, Bridges
Dimensioning
ID (mm) 147.6
OD (mm) 160
Wall thickness (mm) 6.2
Description

Geberit PE drainage system is suitable for a large number of areas of application in roof drainage, in industry, in trade or laboratories, for burial, in concrete or in bridge structures. They are made of the robust pipe material polyethylene with high density (PE-HD). Hot water up to 80 ° C, briefly and without mechanical stress even up to 100 ° C, does not attack the material. It is resistant to around 95% of all commercially available alkalis, acids and chemicals. The pipes and fittings also withstand vibrations, subsidence, impacts or brief pressures of up to 150 kPa (1.5 bar) DN 30-150 without breaking or permanent deformation. The material used, polyethylene, is environmentally friendly and completely recyclable. No toxic emissions are produced during processing or in the event of a fire.

Geberit PE pipes are available in dimensions from DN 30 to DN 300 and with a wide range of fittings. Geberit PE pipes and fittings made of polyethylene meet the requirements of DIN EN 12056 in conjunction with DIN 1986-100, as well as DIN EN 752. The Geberit PE drainage system is for installation inside buildings in accordance with DIN 19535 and DIN EN 1519 and for underground pipes in accordance with DIN EN 12 666-1 approved. Geberit is adapting the designation of the pipe diameter to the requirements of the EN standards. In the past, the nominal diameter DN was used to denote the inner diameter of the pipes. According to the standard, the new nominal size DN approximates the outside diameter of the pipes and fittings.

Material: PE-HD

Linear expansion coefficient: 0.17 mm / (m K)

Absorption of linear expansion: Requires long socket

Installation temperature: -20 to 40 ° C

Application temperature continuous load: -20 to 80 ° C

Chemical resistance: 95% of all commercially available alkalis, acids and chemicals

Source: Geberit Vertriebs GmbH

Flexible pipe connections
CRA10006
Pipe Reducer CGA 150 | 110
150 mm | 110 mm
up to 0.5 bar / 7.3 PSI
CRA10007
Pipe Reducer CGA 178 | 160
178 mm | 160 mm
up to 0.5 bar / 7.3 PSI
CRA12062
Adaptor Coupling CAC 1602
144-160 mm | 110-122 mm
up to 0.6 bar / 8.7 PSI
CRA12063
Adaptor Coupling CAC 1603
144-160 mm | 121-136 mm
up to 0.6 bar / 8.7 PSI
CRA12065
Adaptor Coupling CAC 1702
155-170 mm | 110-125 mm
up to 0.6 bar / 8.7 PSI
CRA17411
Adaptor Coupling CAC 1703
155-170 mm | 130-145 mm
up to 0.6 bar / 8.7 PSI
CRA17417
Adaptor Coupling CAC 1924
170-192 mm | 144-160 mm
up to 0.6 bar / 8.7 PSI
CRA12036
Adaptor Coupling CAC 1500
170-191 mm | 160-170 mm
up to 0.6 bar / 8.7 PSI
CRA17421
Adaptor Coupling CAC 2001
180-200 mm | 155-170 mm
up to 0.6 bar / 8.7 PSI
CRA17034
Adaptor Coupling CAC 6000
180-200 mm | 160-180 mm
up to 0.6 bar / 8.7 PSI
CRA17422
Adaptor Coupling CAC 2002
185-210 mm | 160-180 mm
up to 0.6 bar / 8.7 PSI
CRA17182
Adaptor Coupling CAC 2154
190-215 mm | 150-165 mm
up to 0.6 bar / 8.7 PSI
CRA17183
Adaptor Coupling CAC 2254
200-225 mm | 160-175 mm
up to 0.6 bar / 8.7 PSI
CRA17186
Adaptor Coupling CAC 2354
210-235 mm | 144-160 mm
up to 0.6 bar / 8.7 PSI
CRA17189
Adaptor Coupling CAC 2654
240-265 mm | 144-160 mm
up to 0.6 bar / 8.7 PSI
CRA17194
Adaptor Coupling CAC 2754
250-275 mm | 160-175 mm
up to 0.6 bar / 8.7 PSI
CRA17196
Adaptor Coupling CAC 2904
265-290 mm | 144-160 mm
up to 0.6 bar / 8.7 PSI
CRA17200
Adaptor Coupling CAC 3204
295-320 mm | 144-160 mm
up to 0.6 bar / 8.7 PSI
CRA14032
Drain Coupling CDC 170
150-170 mm
up to 0.6 bar / 8.7 PSI
CRA16202
Drain Coupling CDC 175
160-175 mm
up to 0.6 bar / 8.7 PSI
CRA14041
Standard Coupling CSC 165
140-165 mm
up to 2.5 bar / 36.3 PSI
CRA14042
Standard Coupling CSC 170
150-170 mm
up to 2.5 bar / 36.3 PSI
CRA16216
Standard Coupling CSC 185
160-185 mm
up to 2.5 bar / 36.3 PSI
CRA11023
Plug Adaptor CSA 150
150-168 mm | 145-157 mm
up to 0.5 bar / 7.3 PSI
CRA12062FKM
Adaptor Coupling CAC 1602 FKM
144-160 mm | 110-122 mm
up to 0.6 bar / 8.7 PSI
CRA12063FKM
Adaptor Coupling CAC 1603 FKM
144-160 mm | 121-136 mm
up to 0.6 bar / 8.7 PSI
CRA17417FKM
Adaptor Coupling CAC 1924 FKM
170-192 mm | 144-160 mm
up to 0.6 bar / 8.7 PSI
CRA14032FKM
Standard Coupling CDC 165 FKM
140-165 mm
up to 0.6 bar / 8.7 PSI
CRA14041FKM
Standard Coupling CSC 165 FKM
140-165 mm
up to 2.5 bar / 36.3 PSI
CRA16216FKM
Standard Coupling CSC 185 FKM
160-185 mm
up to 2.5 bar / 36.3 PSI
CRA14056
Drain Coupling CDC 165
140-165 mm
up to 0.6 bar / 8.7 PSI
CRA17422
Adaptor Coupling CAC 2002
185-210 mm | 144-160 mm
up to 0.6 bar / 8.7 PSI
CRA17191
Adaptor Coupling CAC 2656
195-220 mm | 155-170 mm
up to 0.6 bar / 8.7 PSI
Special products
CRA15079
Outside End Cap CEC 165
155-165 mm
up to 0.6 bar / 8.7 PSI

Important: All brand names and trademarks mentioned on this website are the property of their respective owners. The mention of these names and designations is for informational purposes only and does not imply any cooperation or partnership with the respective manufacturers (nominative use). The information and descriptions provided are for general overview purposes and do not constitute binding product advice or recommendation. Despite careful research, no guarantee is given for the completeness, accuracy, or timeliness of the content. All images shown (product images, graphics, etc.) were created by Crassus GmbH & Co. KG or recreated for demonstration purposes. They may differ from the original product. No liability is accepted for material or immaterial damages caused by the use or non-use of the information provided or by the use of incorrect or incomplete information. If manufacturer texts or information are summarized or quoted in our own words, this is done in a manner that respects the copyrights of the respective rights holders. Further use of the content published here requires our express consent and, if necessary, the approval of the respective rights holder.