Adaptor Coupling

Suitable for all wastwater pipes

Variable stainless steel clamp bands

Proofed material quality

Minimal reduction path

Pay attention to flow direction!

Figure
 
Item number
 
A | Size range
(mm)
B | Size range
(mm)
L | Length
(mm)
Material
 
Pressure-tight
(bar)
Thightning torque
(Nm)
Data sheet
 
CRA12027 30-34 24-28 73 EPDM / V2A 0.6 6.0 PDF
CRA12043 32-40 24-32 85 TPE / V2A 0.6 6.0 PDF
CRA12028 38-43 30-35 74 EPDM / V2A 0.6 6.0 PDF
CRA12044 40-50 24-32 87 TPE / V2A 0.6 6.0 PDF
CRA12029 48-56 38-43 75 EPDM / V2A 0.6 6.0 PDF
CRA12047 53-63 40-50 93 EPDM / V2A 0.6 6.0 PDF
CRA12030 60-68 38-43 80 EPDM / V2A 0.6 6.0 PDF
CRA12049 75-89 53-64 90 EPDM / V2A 0.6 6.0 PDF
CRA12031 82-92 48-56 80 EPDM / V2A 0.6 6.0 PDF
CRA12032 82-92 60-68 80 EPDM / V2A 0.6 6.0 PDF
CRA12052 100-115 75-90 95 EPDM / V2A 0.6 6.0 PDF
CRA12039 105-120 35-42 100 EPDM / V2A 0.6 6.0 PDF
CRA12041 110-122 48-56 100 EPDM / V2A 0.6 6.0 PDF
CRA12042 110-122 60-68 100 EPDM / V2A 0.6 6.0 PDF
CRA12040 110-122 80-95 100 EPDM / V2A 0.6 6.0 PDF
CRA12054 110-125 100-115 105 EPDM / V2A 0.6 6.0 PDF
CRA12056 121-136 80-95 105 EPDM / V2A 0.6 6.0 PDF
CRA12057 121-136 100-115 120 EPDM / V2A 0.6 6.0 PDF
CRA12033 121-136 110-121 100 EPDM / V2A 0.6 6.0 PDF
CRA12060 130-145 110-125 120 EPDM / V2A 0.6 6.0 PDF
CRA12062 144-160 110-122 120 EPDM / V2A 0.6 6.0 PDF
CRA12063 144-160 121-136 120 EPDM / V2A 0.6 6.0 PDF
CRA12065 155-170 110-125 120 EPDM / V2A 0.6 6.0 PDF
CRA17411 155-170 130-145 120 EPDM / V2A 0.6 6.0 PDF
CRA17415 170-192 110-122 120 EPDM / V2A 0.6 6.0 PDF
CRA17416 170-192 121-136 120 EPDM / V2A 0.6 6.0 PDF
CRA17417 170-192 144-160 120 EPDM / V2A 0.6 6.0 PDF
CRA12036 170-191 160-170 100 EPDM / V2A 0.6 6.0 PDF
CRA17420 180-200 130-145 150 EPDM / V2A 0.6 6.0 PDF
CRA17421 180-200 155-170 150 EPDM / V2A 0.6 6.0 PDF
CRA17034 180-200 160-180 150 EPDM / V2A 0.6 6.0 PDF
CRA17418 185-210 100-115 150 EPDM / V2A 0.6 6.0 PDF
CRA17422 185-210 160-180 150 EPDM / V2A 0.6 6.0 PDF
CRA17182 190-215 150-165 150 EPDM / V2A 0.6 6.0 PDF
CRA17426 195-215 100-115 150 EPDM / V2A 0.6 6.0 PDF
CRA17183 200-225 160-175 150 EPDM / V2A 0.6 6.0 PDF
CRA17184 210-235 110-122 150 EPDM / V2A 0.6 6.0 PDF
CRA17185 210-235 121-136 150 EPDM / V2A 0.6 6.0 PDF
CRA17186 210-235 144-160 150 EPDM / V2A 0.6 6.0 PDF
CRA17187 210-235 170-192 150 EPDM / V2A 0.6 6.0 PDF
CRA17188 210-235 190-215 150 EPDM / V2A 0.6 6.0 PDF
CRA17189 240-265 144-160 150 EPDM / V2A 0.6 6.0 PDF
CRA17190 240-265 170-192 150 EPDM / V2A 0.6 6.0 PDF
CRA17191 240-265 190-215 150 EPDM / V2A 0.6 6.0 PDF
CRA17193 240-265 210-235 150 EPDM / V2A 0.6 6.0 PDF
CRA17194 250-275 160-175 150 EPDM / V2A 0.6 6.0 PDF
CRA17195 250-275 200-225 150 EPDM / V2A 0.6 6.0 PDF
CRA12035 260-285 180-205 150 EPDM / V2A 0.6 10.0 PDF
CRA17037 260-285 240-250 130 EPDM / V2A 0.6 6.0 PDF
CRA17196 265-290 144-160 150 EPDM / V2A 0.6 10.0 PDF
CRA17197 265-290 210-235 150 EPDM / V2A 0.6 10.0 PDF
CRA17198 265-290 235-260 150 EPDM / V2A 0.6 10.0 PDF
CRA17199 270-295 185-210 150 EPDM / V2A 0.6 10.0 PDF
CRA17200 295-320 144-160 150 EPDM / V2A 0.6 10.0 PDF
CRA17201 295-320 170-192 150 EPDM / V2A 0.6 10.0 PDF
CRA17206 295-320 210-235 150 EPDM / V2A 0.6 10.0 PDF
CRA17207 295-320 240-265 150 EPDM / V2A 0.6 10.0 PDF
CRA17208 295-320 265-290 150 EPDM / V2A 0.6 10.0 PDF
CRA17209 310-335 180-205 150 EPDM / V2A 0.6 10.0 PDF
CRA17210 335-360 240-265 165 EPDM / V2A 0.6 10.0 PDF
CRA17211 335-360 265-290 165 EPDM / V2A 0.6 10.0 PDF
CRA17212 335-360 295-320 165 EPDM / V2A 0.6 10.0 PDF
CRA17213 360-385 240-265 165 EPDM / V2A 0.6 10.0 PDF
CRA17214 360-385 265-290 165 EPDM / V2A 0.6 10.0 PDF
CRA17215 360-385 300-325 165 EPDM / V2A 0.6 10.0 PDF
CRA17038 360-385 325-335 160 EPDM / V2A 0.6 10.0 PDF
CRA17228 395-420 240-265 165 EPDM / V2A 0.6 10.0 PDF
CRA17242 395-420 265-290 165 EPDM / V2A 0.6 10.0 PDF

Problem

You have two sewer pipes and you need a reliable connection, even with different materials and outside diameters of the pipes.


Solution (1/4)

Loosen the clamp bands a little.


Solution (2/4)

Push the Crassus Adaptor Coupling over the first cleaned pipe and tighten the clamp band.


Solution (3/4)

Now you can push the smaller pipe into the adaptor coupling (if necessary use lubricant) and tighten the second clamp band.


Solution (4/4)

You have created a professional and tight connection.

Downloads
Filetype and name Size
Approval Eta 12 0410 Eng Cac Cdc Ctc Csc 3.35 MB
Crassus Product Overview Adaptor Calculation Table A3 1.31 MB